Virtualization: The Foundation of a
     Data Center Green IT Business Case



Ted Ritter
Senior Research Analyst
Nemertes Research
ted.ritter@nemertes.com
Agenda

     Introductions
     Virtualization Trends
     Green/Sustainability Status
     Power Challenges
     Power Cost Modeling with Virtualization
     ROI Reality
     Virtualization Green Reality
     Conclusions and Recommendations
    Q&A




2        © Nemertes Research 2010   www.nemertes.com   1-888-241-2685
Introductions: About Nemertes
     Analyze business value of
      emerging technologies
     Advise and Assist Fortune 100-
      2,000 businesses on critical IT
      strategies
     Benchmark reality
     2,500+ IT executives share
      strategies, costs, vendor
      satisfaction
     Analysts have 17-30 years
      experience, including
      operational
     Founded 2002


3           © Nemertes Research 2010   www.nemertes.com   1-888-241-2685
Virtualization Trends
     Server Virtualization:
         93% implementing server virtualization
         21% “full implementation”
     Desktop Virtualization: More than 20% now
         Growing over next two years
     Benefits:
         Cost savings (power, server hardware)
         Agility (provisioning times drop by 80%+)
         Disaster recovery (74% increase in “less-than-an-hour” site recovery times)
     Cautions
         Servers: security, management
         Desktops: careful attention to service engineering, TCO
     Application Virtualization: 10% now, set to grow more slowly than
      desktop virtualization
     Few using cloud computing today, but looking to do it in future




4          © Nemertes Research 2010   www.nemertes.com   1-888-241-2685
Why Virtualize?




5   © Nemertes Research 2010   www.nemertes.com   1-888-241-2685
Why Virtualize Desktops?




6   © Nemertes Research 2010   www.nemertes.com   1-888-241-2685   © Copyright 2009 Nemertes Research
Green/Sustainability Status




7   © Nemertes Research 2010   www.nemertes.com   1-888-241-2685
The Green Data Center: Sustainability Policy



                                                                         50% of
                                                                   organizations have
                                                                   quantified a benefit
                                                                   from sustainability




8   © Nemertes Research 2010   www.nemertes.com   1-888-241-2685
Power Density



                                                16 KW
                                                                  Rack of
                                                                  Blade
                                                                  Chassis
                                                12 KW             (64)          Typical Co-
                                                                                location
                                                                                Power

                                                8 KW



                                                4 KW              Full Blade Chassis (16)
                                                                  Rack of 1U Servers (16)




9   © Nemertes Research 2010 www.nemertes.com    1-888-241-2685
Power Challenges




10   © Nemertes Research 2010   www.nemertes.com   1-888-241-2685
HVAC Challenges




11   © Nemertes Research 2010 www.nemertes.com   1-888-241-2685
Response to HVAC Challenges




12   © Nemertes Research 2010 www.nemertes.com   1-888-241-2685
Power Usage Metric - PUE

 Only 35% - 50% of power
  actually reaches IT                                              3.0
                                                                               2.86 – 35%
  equipment                                                                    IT Power
       HVAC consumes 45% of power
       Power transmission-conversion
        loss consumes 5 - 20%                    43%               2.0
                                                                               1.87 – Research
 Only 45% of organizations                     More
                                                                               Participants
                                                  IT
  measure data center
                                                Power                          1.37 – Fortune
  power                                                                        Data Center
 Only 15% of organizations                                        1.0
                                                                               < 1.0 - ????
  have a power efficiency
  metric
                                                                   Main Power Feed
              Power Use Efficiency (PUE) =
                                                       Power Reaching IT Equipment


 13            © Nemertes Research 2010   www.nemertes.com   1-888-241-2685
Power Cost Modeling




14   © Nemertes Research 2010   www.nemertes.com   1-888-241-2685
Desktop Virtualization Factors


                                                                    18000
                                                                   Current
                                                                  Desktops


                                    Four year lifespan
                                   85 Watt Power Draw




                                                  20% Systems
                                                  Replaced by
                                                                               16 Watts
                                                   Thin Clients
                                                                             Average thin
                                                                                client




15   © Nemertes Research 2010   www.nemertes.com     1-888-241-2685
New Enterprise Desktop – Post-Virtualization




     Transition
      to Thin
       Client

                       Account
                      for Server
                        Power
                                           97% Pre-                        90% Pre-
                                          Virtualizatio                   Virtualizatio
                                            n Power                         n Power




16           © Nemertes Research 2010 www.nemertes.com   1-888-241-2685
Server Virtualization Factors


                                                             Server Power
                                                              450 Watts




                                                               5000 Pre Virtualization Servers
                                                              1400 Post-Virtualization Servers



                                           Stage of
                                        Virtualization
                                           - Partial


                                                               Power Cost
                                                                $0.12 per
                                                                  kWh




17   © Nemertes Research 2010   www.nemertes.com     1-888-241-2685
Server Virtualization Business Case: Small
                                  Server Virtualization: Cost and Returns
                                                                                      Without                 With
 In a 200 server infrastructure                                                     Virtualization        Virtualization
 Number of new servers per year (lifecycle)                                                      57                    10
                                                                                       Without              With
                               Capital Costs                                        Virtualization        Virtualization
 Servers                                                                                  171429                 42857
 Cost of associated network infrastructure (annualized)                                       429                   476

 Cost of associated storage network (annualized)                                             2000                  1029

 Annual Capital Costs                                                          $ 173,857.14           $    44,361.90
                                                                                      Without          71% Pre-
                                                                                                            With
                            Operational Costs                                       Virtualization      Virtualization
                                                                                                      Virtualizatio
 Admin time to rack and stack them (staff hours)                                                 71     n Power12
 Admin cost to rack and stack them                                                           3214                   536
 Cost of power (annual)                                                                    94608                 66856

 Annual Operational Costs                                                      $     97,822.29        $    67,392.03

                             Annual Expenses                                   $ 271,679.43           $ 111,753.94




18               © Nemertes Research 2010       www.nemertes.com   1-888-241-2685
Server Virtualization Business Case: Large
                                  Server Virtualization: Cost and Returns
                                                                            Without             Moving to
     In a 5000 server infrastructure                                     Virtualization       Virtualization

     Number of new servers per year (lifecycle)                                       1429                     238

                              Capital Costs
     Servers                                                                      4285714              1071429
     Cost of associated network infrastructure (annualized)                           10714               11905
     Cost of associated storage network (annualized)                                  50000               25714

     Annual Capital Costs                                               $ 4,346,428.57        $ 1,109,047.62
                                                                                                     71% Pre-
                         Operational Costs
                                                                                                    Virtualizatio
     Admin time to rack and stack them (staff hours)                                  1786            n Power
                                                                                                          298
     Admin cost to rack and stack them                                                80357               13393
     Cost of power (annual)                                                       2365200              1671408

     Annual Operational Costs                                           $ 2,445,557.14        $ 1,684,800.86

                         Annual Expenses                                $ 6,791,985.71        $ 2,793,848.48




19               © Nemertes Research 2010         www.nemertes.com   1-888-241-2685
ROI Analysis



                                      3 Year ROI
                                         392%




                                                                      OpEx
                        91% OpEx                                    Savings of
                        savings is                                  $2,282,269
                          power




20   © Nemertes Research 2010   www.nemertes.com   1-888-241-2685
ROI Reality - ROI Improves With Maturity




21   © Nemertes Research 2010   www.nemertes.com   1-888-241-2685
Maturity vs. Server Power Load




22   © Nemertes Research 2010   www.nemertes.com   1-888-241-2685
Virtualization Green Reality

      OpEx: The power of virtualization
         Power – the most significant OpEx reduction factor
         No participant from a large organization knew their data center power usage
         Every server kWh reduced is 3 kWh on the meter
      Size matters
         Larger data centers show greater returns
         Key factors are stacking depth and annual expansion
      Maturity pays off
         ROI increases by stage: Evaluation to pilot to partial to full roll-out the ROI
         Expect a negative ROI during evaluation stage – duplication of resources
      Poor storage planning will eat virtualization returns
         Participants report spiraling storage requirements



23         © Nemertes Research 2010   www.nemertes.com   1-888-241-2685
Conclusions and Recommendations

      Need to start with power metrics – PUE
      Focus on low-hanging fruit
         Server virtualization to consolidate older less efficient servers onto more
          powerful and more efficient servers
         Caution – watch out for power and heat density potential issues
      Desktop virtualization power savings complicated
         Often desktop power use is not on “your nickel”
         Desktop virtualization extends the life of desktops
      Look to power optimizing solutions from companies like
       Avocent, Cisco and Microsoft to conserve power
       independent of virtualization efforts



24         © Nemertes Research 2010   www.nemertes.com   1-888-241-2685
Thank you!
                                                   Questions?
                                             Research@nemertes.com




25   © Nemertes Research 2010   www.nemertes.com   1-888-241-2685

More Related Content

Similar to 10 fn s38

Sun sparc enterprise t5140 and t5240 servers customer presentation
Sun sparc enterprise t5140 and t5240 servers customer presentationSun sparc enterprise t5140 and t5240 servers customer presentation
Sun sparc enterprise t5140 and t5240 servers customer presentationxKinAnx
 
Data Center Infrastructure Trends
Data Center Infrastructure TrendsData Center Infrastructure Trends
Data Center Infrastructure TrendsViridity Software
 
EatonVirtualization, Connectivity and the Cloud — Trends Driving the Future o...
EatonVirtualization, Connectivity and the Cloud — Trends Driving the Future o...EatonVirtualization, Connectivity and the Cloud — Trends Driving the Future o...
EatonVirtualization, Connectivity and the Cloud — Trends Driving the Future o...Spiceworks
 
X.DAYS Service Provider Pitch Interlaken Swiss
X.DAYS Service Provider Pitch Interlaken SwissX.DAYS Service Provider Pitch Interlaken Swiss
X.DAYS Service Provider Pitch Interlaken SwissRuud van Zutphen ⛅️
 
2013-03-11-seminario-artecs-mzapater
2013-03-11-seminario-artecs-mzapater2013-03-11-seminario-artecs-mzapater
2013-03-11-seminario-artecs-mzapatergreendisc
 
The Road to Data Center Energy Efficiency
The Road to Data Center Energy EfficiencyThe Road to Data Center Energy Efficiency
The Road to Data Center Energy EfficiencyViridity Software
 
Forrester New Star Faronics Power Save Webinar Sept 22, 2009
Forrester   New Star   Faronics Power Save Webinar   Sept 22, 2009Forrester   New Star   Faronics Power Save Webinar   Sept 22, 2009
Forrester New Star Faronics Power Save Webinar Sept 22, 2009jsmithwick0926
 
Data Center Optimization with Avocent MergePoint Infrastructure Explorer (AMIE)
Data Center Optimization with Avocent MergePoint Infrastructure Explorer (AMIE)Data Center Optimization with Avocent MergePoint Infrastructure Explorer (AMIE)
Data Center Optimization with Avocent MergePoint Infrastructure Explorer (AMIE)42U Data Center Solutions
 
Sustainable IT for Energy Management: Approaches, Challenges, and Trends
Sustainable IT for Energy Management: Approaches, Challenges, and TrendsSustainable IT for Energy Management: Approaches, Challenges, and Trends
Sustainable IT for Energy Management: Approaches, Challenges, and TrendsEdward Curry
 
Benchmark the Relative Performance of Your Data Center
Benchmark the Relative Performance of Your Data CenterBenchmark the Relative Performance of Your Data Center
Benchmark the Relative Performance of Your Data CenterAFCOM
 
Ppt4 london - michael rudgyard ( concurrent thinking ) driving efficiencie...
Ppt4   london -  michael rudgyard ( concurrent thinking ) driving efficiencie...Ppt4   london -  michael rudgyard ( concurrent thinking ) driving efficiencie...
Ppt4 london - michael rudgyard ( concurrent thinking ) driving efficiencie...JISC's Green ICT Programme
 
Dhana Raj Markandu: Evolution of the PI System in Tenaga's Power Generation F...
Dhana Raj Markandu: Evolution of the PI System in Tenaga's Power Generation F...Dhana Raj Markandu: Evolution of the PI System in Tenaga's Power Generation F...
Dhana Raj Markandu: Evolution of the PI System in Tenaga's Power Generation F...Dhana Raj Markandu
 
Virtualization for Power Industry
Virtualization for Power IndustryVirtualization for Power Industry
Virtualization for Power IndustryAvanceon-Lahore
 
Improved efficiency & reliability for servers using immersion cooling technology
Improved efficiency & reliability for servers using immersion cooling technologyImproved efficiency & reliability for servers using immersion cooling technology
Improved efficiency & reliability for servers using immersion cooling technologyASQ Reliability Division
 

Similar to 10 fn s38 (20)

Sun sparc enterprise t5140 and t5240 servers customer presentation
Sun sparc enterprise t5140 and t5240 servers customer presentationSun sparc enterprise t5140 and t5240 servers customer presentation
Sun sparc enterprise t5140 and t5240 servers customer presentation
 
Data Center Infrastructure Trends
Data Center Infrastructure TrendsData Center Infrastructure Trends
Data Center Infrastructure Trends
 
Unified Communications
Unified CommunicationsUnified Communications
Unified Communications
 
EatonVirtualization, Connectivity and the Cloud — Trends Driving the Future o...
EatonVirtualization, Connectivity and the Cloud — Trends Driving the Future o...EatonVirtualization, Connectivity and the Cloud — Trends Driving the Future o...
EatonVirtualization, Connectivity and the Cloud — Trends Driving the Future o...
 
Euro Green IT Innovation Center - Climate Savers Computing
Euro Green IT Innovation Center - Climate Savers Computing Euro Green IT Innovation Center - Climate Savers Computing
Euro Green IT Innovation Center - Climate Savers Computing
 
An Introduction to CSCI
An Introduction to CSCIAn Introduction to CSCI
An Introduction to CSCI
 
X.DAYS Service Provider Pitch Interlaken Swiss
X.DAYS Service Provider Pitch Interlaken SwissX.DAYS Service Provider Pitch Interlaken Swiss
X.DAYS Service Provider Pitch Interlaken Swiss
 
2013-03-11-seminario-artecs-mzapater
2013-03-11-seminario-artecs-mzapater2013-03-11-seminario-artecs-mzapater
2013-03-11-seminario-artecs-mzapater
 
The Road to Data Center Energy Efficiency
The Road to Data Center Energy EfficiencyThe Road to Data Center Energy Efficiency
The Road to Data Center Energy Efficiency
 
Forrester New Star Faronics Power Save Webinar Sept 22, 2009
Forrester   New Star   Faronics Power Save Webinar   Sept 22, 2009Forrester   New Star   Faronics Power Save Webinar   Sept 22, 2009
Forrester New Star Faronics Power Save Webinar Sept 22, 2009
 
Gamatronics Solutions for Data Centers
Gamatronics Solutions for Data CentersGamatronics Solutions for Data Centers
Gamatronics Solutions for Data Centers
 
Data Center Optimization with Avocent MergePoint Infrastructure Explorer (AMIE)
Data Center Optimization with Avocent MergePoint Infrastructure Explorer (AMIE)Data Center Optimization with Avocent MergePoint Infrastructure Explorer (AMIE)
Data Center Optimization with Avocent MergePoint Infrastructure Explorer (AMIE)
 
LCOE_2015_2_pager_US
LCOE_2015_2_pager_USLCOE_2015_2_pager_US
LCOE_2015_2_pager_US
 
Sustainable IT for Energy Management: Approaches, Challenges, and Trends
Sustainable IT for Energy Management: Approaches, Challenges, and TrendsSustainable IT for Energy Management: Approaches, Challenges, and Trends
Sustainable IT for Energy Management: Approaches, Challenges, and Trends
 
PUE Reconsidered
PUE ReconsideredPUE Reconsidered
PUE Reconsidered
 
Benchmark the Relative Performance of Your Data Center
Benchmark the Relative Performance of Your Data CenterBenchmark the Relative Performance of Your Data Center
Benchmark the Relative Performance of Your Data Center
 
Ppt4 london - michael rudgyard ( concurrent thinking ) driving efficiencie...
Ppt4   london -  michael rudgyard ( concurrent thinking ) driving efficiencie...Ppt4   london -  michael rudgyard ( concurrent thinking ) driving efficiencie...
Ppt4 london - michael rudgyard ( concurrent thinking ) driving efficiencie...
 
Dhana Raj Markandu: Evolution of the PI System in Tenaga's Power Generation F...
Dhana Raj Markandu: Evolution of the PI System in Tenaga's Power Generation F...Dhana Raj Markandu: Evolution of the PI System in Tenaga's Power Generation F...
Dhana Raj Markandu: Evolution of the PI System in Tenaga's Power Generation F...
 
Virtualization for Power Industry
Virtualization for Power IndustryVirtualization for Power Industry
Virtualization for Power Industry
 
Improved efficiency & reliability for servers using immersion cooling technology
Improved efficiency & reliability for servers using immersion cooling technologyImproved efficiency & reliability for servers using immersion cooling technology
Improved efficiency & reliability for servers using immersion cooling technology
 

More from Scott Foster (20)

10 fn tut3
10 fn tut310 fn tut3
10 fn tut3
 
10 fn tut2
10 fn tut210 fn tut2
10 fn tut2
 
10 fn tut1
10 fn tut110 fn tut1
10 fn tut1
 
10 fn s48
10 fn s4810 fn s48
10 fn s48
 
10 fn s47
10 fn s4710 fn s47
10 fn s47
 
10 fn s46
10 fn s4610 fn s46
10 fn s46
 
10 fn s45
10 fn s4510 fn s45
10 fn s45
 
10 fn s44
10 fn s4410 fn s44
10 fn s44
 
10 fn s43
10 fn s4310 fn s43
10 fn s43
 
10 fn s42
10 fn s4210 fn s42
10 fn s42
 
10 fn s40
10 fn s4010 fn s40
10 fn s40
 
10 fn s37
10 fn s3710 fn s37
10 fn s37
 
10 fn s36
10 fn s3610 fn s36
10 fn s36
 
10 fn s35
10 fn s3510 fn s35
10 fn s35
 
10 fn s34
10 fn s3410 fn s34
10 fn s34
 
10 fn s33
10 fn s3310 fn s33
10 fn s33
 
10 fn s32
10 fn s3210 fn s32
10 fn s32
 
10 fn s31
10 fn s3110 fn s31
10 fn s31
 
10 fn s29
10 fn s2910 fn s29
10 fn s29
 
10 fn s28
10 fn s2810 fn s28
10 fn s28
 

10 fn s38

  • 1. Virtualization: The Foundation of a Data Center Green IT Business Case Ted Ritter Senior Research Analyst Nemertes Research ted.ritter@nemertes.com
  • 2. Agenda  Introductions  Virtualization Trends  Green/Sustainability Status  Power Challenges  Power Cost Modeling with Virtualization  ROI Reality  Virtualization Green Reality  Conclusions and Recommendations Q&A 2 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 3. Introductions: About Nemertes  Analyze business value of emerging technologies  Advise and Assist Fortune 100- 2,000 businesses on critical IT strategies  Benchmark reality  2,500+ IT executives share strategies, costs, vendor satisfaction  Analysts have 17-30 years experience, including operational  Founded 2002 3 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 4. Virtualization Trends  Server Virtualization:  93% implementing server virtualization  21% “full implementation”  Desktop Virtualization: More than 20% now  Growing over next two years  Benefits:  Cost savings (power, server hardware)  Agility (provisioning times drop by 80%+)  Disaster recovery (74% increase in “less-than-an-hour” site recovery times)  Cautions  Servers: security, management  Desktops: careful attention to service engineering, TCO  Application Virtualization: 10% now, set to grow more slowly than desktop virtualization  Few using cloud computing today, but looking to do it in future 4 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 5. Why Virtualize? 5 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 6. Why Virtualize Desktops? 6 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685 © Copyright 2009 Nemertes Research
  • 7. Green/Sustainability Status 7 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 8. The Green Data Center: Sustainability Policy 50% of organizations have quantified a benefit from sustainability 8 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 9. Power Density 16 KW Rack of Blade Chassis 12 KW (64) Typical Co- location Power 8 KW 4 KW Full Blade Chassis (16) Rack of 1U Servers (16) 9 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 10. Power Challenges 10 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 11. HVAC Challenges 11 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 12. Response to HVAC Challenges 12 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 13. Power Usage Metric - PUE  Only 35% - 50% of power actually reaches IT 3.0 2.86 – 35% equipment IT Power  HVAC consumes 45% of power  Power transmission-conversion loss consumes 5 - 20% 43% 2.0 1.87 – Research  Only 45% of organizations More Participants IT measure data center Power 1.37 – Fortune power Data Center  Only 15% of organizations 1.0 < 1.0 - ???? have a power efficiency metric Main Power Feed Power Use Efficiency (PUE) = Power Reaching IT Equipment 13 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 14. Power Cost Modeling 14 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 15. Desktop Virtualization Factors 18000 Current Desktops Four year lifespan 85 Watt Power Draw 20% Systems Replaced by 16 Watts Thin Clients Average thin client 15 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 16. New Enterprise Desktop – Post-Virtualization Transition to Thin Client Account for Server Power 97% Pre- 90% Pre- Virtualizatio Virtualizatio n Power n Power 16 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 17. Server Virtualization Factors Server Power 450 Watts 5000 Pre Virtualization Servers 1400 Post-Virtualization Servers Stage of Virtualization - Partial Power Cost $0.12 per kWh 17 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 18. Server Virtualization Business Case: Small Server Virtualization: Cost and Returns Without With In a 200 server infrastructure Virtualization Virtualization Number of new servers per year (lifecycle) 57 10 Without With Capital Costs Virtualization Virtualization Servers 171429 42857 Cost of associated network infrastructure (annualized) 429 476 Cost of associated storage network (annualized) 2000 1029 Annual Capital Costs $ 173,857.14 $ 44,361.90 Without 71% Pre- With Operational Costs Virtualization Virtualization Virtualizatio Admin time to rack and stack them (staff hours) 71 n Power12 Admin cost to rack and stack them 3214 536 Cost of power (annual) 94608 66856 Annual Operational Costs $ 97,822.29 $ 67,392.03 Annual Expenses $ 271,679.43 $ 111,753.94 18 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 19. Server Virtualization Business Case: Large Server Virtualization: Cost and Returns Without Moving to In a 5000 server infrastructure Virtualization Virtualization Number of new servers per year (lifecycle) 1429 238 Capital Costs Servers 4285714 1071429 Cost of associated network infrastructure (annualized) 10714 11905 Cost of associated storage network (annualized) 50000 25714 Annual Capital Costs $ 4,346,428.57 $ 1,109,047.62 71% Pre- Operational Costs Virtualizatio Admin time to rack and stack them (staff hours) 1786 n Power 298 Admin cost to rack and stack them 80357 13393 Cost of power (annual) 2365200 1671408 Annual Operational Costs $ 2,445,557.14 $ 1,684,800.86 Annual Expenses $ 6,791,985.71 $ 2,793,848.48 19 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 20. ROI Analysis 3 Year ROI 392% OpEx 91% OpEx Savings of savings is $2,282,269 power 20 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 21. ROI Reality - ROI Improves With Maturity 21 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 22. Maturity vs. Server Power Load 22 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 23. Virtualization Green Reality  OpEx: The power of virtualization  Power – the most significant OpEx reduction factor  No participant from a large organization knew their data center power usage  Every server kWh reduced is 3 kWh on the meter  Size matters  Larger data centers show greater returns  Key factors are stacking depth and annual expansion  Maturity pays off  ROI increases by stage: Evaluation to pilot to partial to full roll-out the ROI  Expect a negative ROI during evaluation stage – duplication of resources  Poor storage planning will eat virtualization returns  Participants report spiraling storage requirements 23 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 24. Conclusions and Recommendations  Need to start with power metrics – PUE  Focus on low-hanging fruit  Server virtualization to consolidate older less efficient servers onto more powerful and more efficient servers  Caution – watch out for power and heat density potential issues  Desktop virtualization power savings complicated  Often desktop power use is not on “your nickel”  Desktop virtualization extends the life of desktops  Look to power optimizing solutions from companies like Avocent, Cisco and Microsoft to conserve power independent of virtualization efforts 24 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685
  • 25. Thank you! Questions? Research@nemertes.com 25 © Nemertes Research 2010 www.nemertes.com 1-888-241-2685